Fitting Room Mirror Lighting Calculator Australia

Estimate vertical mirror lighting count, maintained lux and load for one fitting-room mirror.

Mirror face

Mirror size, target and fitting data

Estimate fitting-room mirror or face-plane lighting.

Width of the desk row, counter, wall, mirror, shelf face or target surface.

Height of the vertical face, wall, mirror or presentation surface.

Maintained lux target for the task or workplane.

Published output for one luminaire.

Input power for one luminaire.

Conservative allowance for light reaching the vertical target face.

Allowance for ageing, dirt and lumen depreciation.

Distance from the light source to the target surface along the aimed path.

Published beam angle for the fitting.

Formula

mirror surface area = width x height; required lumens = area x target lux / (vertical UF x MF); optional beam diameter uses throw and beam angle

Mirror face area x target lux is adjusted by vertical utilisation and maintenance factors before fitting count and load are reported.

VariableTechnical meaningDesign check
Surface areaWidth multiplied by height.Use the visible vertical target.
Vertical allowanceVUF and maintenance factor applied to fitting output.Keep the assumption visible.
Fitting countRequired vertical lumens divided by one fitting output.Rounded up to whole fittings.
Optional beamThrow and beam angle describe coverage only.No glare review or sign-off result.
BoundaryVertical planning estimateNo formal assessment or sign-off result.