Luminaire Markings Table

Common luminaire and lamp markings used in Australian lighting calculations and checks.

Table PDFLuminaire Markings Table

Download the table with the page URL and retrieval date for offline lighting checks.

MarkingMeaningCalculation useBoundary
lmLuminous flux output.Used for lumen targets, fixture count and lux estimates.Use delivered lumens where the data distinguishes source and fitting output.
WElectrical input power.Used for connected load and running-cost estimates.Watts do not describe brightness without lumen output.
K or CCTCorrelated colour temperature.Used for appearance grouping such as warm, neutral or cool white.CCT does not describe colour rendering quality.
CRI or RaColour rendering index.Used as a colour quality cue for task and display contexts.Do not treat one CRI number as a full spectral assessment.
IPIngress protection code.Used to compare enclosure protection against solids and water.IP marking does not replace location and installation checks.
DimmableControl compatibility statement.Used to flag that a fitting may require a matching control method.It is not a guarantee with every dimmer, driver or load condition.