Maintenance Factor Table

Table rows for maintenance factor assumptions in maintained-lighting calculations.

Clean, actively maintained space
MF 0.90
Controlled interior allowance
MF 0.80
Uncertain maintenance allowance
MF 0.70
Severe depreciation allowance
MF 0.60
Table PDFMaintenance Factor Table

Download the table with the page URL and retrieval date for offline lighting checks.

MF bandAssumptionEffect on lumen targetBoundary
0.90Clean maintained space with supported depreciation, access and cleaning evidence.Required lumens = target lumens / 0.90 before UF.Keep the evidence beside the estimate; this band should not become the default.
0.80Ordinary preliminary allowance for controlled interiors with a plausible maintenance routine.Required lumens = target lumens / 0.80 before UF.Still an assumption, not a measured maintained-light outcome.
0.70Dirt, ageing, access or maintenance uncertainty that may reduce delivered light.Required lumens = target lumens / 0.70 before UF.Use for sensitivity checks while the actual maintenance record is uncertain.
0.60Severe depreciation, poor access, dusty conditions or weak maintenance evidence.Required lumens = target lumens / 0.60 before UF.Needs project-specific evidence before it is used in a design record.
Measured planMeasured depreciation, cleaning interval, luminaire data and replacement records.Replaces generic MF assumptions in formal maintained-light calculations.Use the applicable source method and project record rather than a public-table shortcut.

Related pages