Covered Balcony Lighting Load Calculator Australia

Estimate fitting count, maintained lux and scene load for a covered private balcony.

Covered balcony

Area, target, fitting data and scene output

Estimate normal lighting count and load for a covered private balcony.

Measured floor area or task-plane area.

Maintained lux target for the task or workplane.

Published output for one luminaire.

Input power for one luminaire.

Allowance for light reaching the workplane.

Allowance for ageing, dirt and lumen depreciation.

Typical dimmed output level for the local scene load note.

Formula

required lumens = area x target lux / (UF x MF); count is rounded to whole fittings; scene load = connected load x scene output

Required lumens = area x target lux / (UF x MF). Count is rounded to whole fittings. Connected load and scene load are reported from the rounded count.

VariableTechnical meaningDesign check
Lumen demandarea x target lux / (UF x MF)Planning target.
Fitting countceiling(required lumens / fitting lumens)Whole fittings.
Estimated luxinstalled lumens x UF x MF / areaRounded-count check.
Scene loadconnected load x scene outputControl-state note.
BoundaryCovered balcony estimateNo wet-area suitability result.