Facade Wall Wash Lighting Calculator Australia

Estimate private facade wall-wash count, spacing, overlap and connected load.

Facade wash

Facade length, setback, beam and watts

Estimate private facade wall-wash count, centres and load.

Length of the wall, facade, shelf face or display run being lit.

Distance from the luminaire line to the wall, face or washed surface.

Published beam angle for the fitting.

Beam overlap allowance used to set practical spacing.

Input power for one luminaire.

Formula

beam width = 2 x setback x tan(beam angle / 2); count = ceiling(wall length / target spacing) + 1; load = count x watts

Beam width = 2 x setback x tan(beam angle / 2). Spacing uses the entered overlap, count is rounded up, and connected load is count x watts.

VariableTechnical meaningDesign check
Beam width2 x setback x tan(angle / 2)Footprint at the facade.
Target spacingbeam width x (1 - overlap)Planning assumption.
Fitting countceiling(wall length / target spacing) + 1Whole fittings.
Connected loadcount x watts per fittingLoad note only.
BoundaryPrivate facade estimateNo spill-limit or permission result.