Room Zone Split Lighting Calculator Australia

Estimate lumens, fitting count, maintained lux and load for one task, ambient or accent zone inside a room.

Room zone

Zone area, target lux and fitting data

Enter one task, ambient or accent zone inside a room. The result reports local lumens, count, estimated lux and load alongside the whole-room take-off.

Measured area for this room zone, bench, shelf face, task surface or work bay.

Maintained lux target for the task or workplane.

Published output for one luminaire.

Input power for one luminaire.

Allowance for light reaching the workplane.

Allowance for ageing, dirt and lumen depreciation.

Formula

required lumens = zone area x target lux / (UF x MF); fitting count = ceiling(required lumens / lumens per fitting); estimated lux = installed lumens x UF x MF / zone area

Area x target lux gives the zone lumen demand. UF and MF adjust the allowance before the required lumens are divided by one fitting output and rounded up to whole fittings.

VariableTechnical meaningDesign check
Zone areaMeasured task, ambient or accent area.Split the room when surface, height or control changes.
Target luxMaintained illuminance for the named zone.Do not apply one high task value to the whole room by default.
Lumens per fittingPublished output for the selected luminaire.Keep output, beam and mounting role together.
UF and MFDelivery and maintenance assumptions.Dark finishes or difficult maintenance justify lower factors.
Connected loadFitting count multiplied by input watts.Energy and load note only, not electrical design.